I M P O R T A N T Remote Monitoring Agent Release Notes - V9.10C ============================================== V9.10C ------ 1. Added support for PCR-1000 and PCR-1500 real time band scope over network. V9.00M ------ 1. Corrected problem that stopped scanning when any member leaves a multiple monitoring session. 2. Corrected problem that caused received status to be incorrect when multiple monitoring users connected. V9.00D ------ 1. Corrected problem that prevented using COM ports of COM10 or above. 2, Enhanced AR8600 MKII s meter accuracy. 3. Corrected problem with AR8600/AR8200 spectrum analysis. 4. Added wide band FM mode to AR8600/AR8200 spectrum analysis. 5. Improved signal level to -dBm conversion on AR8600. V8.85X ------ 1. Corrected problem that prevented lite client users from accessing a full server when an access password was set. V8.85R ------ 1. Corrected problem with remote server lite password authentication. Changes in V8.85O ----------------- 1. Corrected problem related to disk space query causing divide by zero fault on some hard disk drives. 2. Imporved operation of shutdown processing. Changes in V8.85N ----------------- 1. Corrected problem with WJ-8611 driver. 2. Corrected minor issue with squelch control knob on RX-340. 3. Corrected minor issue with sideband selector on RX-340. 4. Corrected minor issue with user programmable AGC settings on RX-340. 5. Corrected problem with WJ 8711 noise blanker setting not restored properly. 6. Corrected problem with SAM mode on some WJ receivers. 7. Corrected problem with sideband selection switch on WJ HF receivers. 8. Corrected minor issue with squelch control knob on various WJ receivers. 9. Corrected problem with PCR-1000 signal strength meter. 10. Added support for AOR SR-2200. 11. Corrected problem with various Uniden trunk-tracking scanners related to audio recording. 12. Corrected problems with WJ 8615/8617/8618 driver. Improved performance. 13. Improved reliability of ID hold functions on BC796D/BC785D when operated remotely. 14. Corrected problem where selected audio compression format not saved and set correctly. 15. Correcter problem where selected audio compression format not applied to all configured radios. Changes in V8.85E ----------------- 1. Added support for remote server lite clients. 2. Corrected rare problem that cause lock up condition when using remote radios and the link is disconnected immediately after the connection is established. 3. Updated 4. Added decoder for Connect Systems LT-2 LTR decoder. 5. Improved RC95S driver. 6. Improved views and drivers for SI-8616, SI-8614, WJ-860X, WJ-8654. Changes in V8.83Y ----------------- 1. Fixed problem with correct audio line configuration. 2. Audio monitor output is muted while in playback. Changes in V8.83X ----------------- 1. Fixed problem on OptoScan/OptoCom driver that caused PL/DPL decoding to fail on radios with older firmware. 2. Fixed problem on OptoScan/OptoCom that prevented PL/DPL codes from appearing on search ranges. 3. Improved features and capability of URDC feature. Changes in V8.83U ----------------- 1. Improved networking reaction to routing table changes. 2. Agent now detects when IP routing changes after modem answers RAS call. Changes in V8.83N ----------------- 1. Implemented new protocol features. 2. Fixed problems with Icom IC-706. 3. Improved operation of continuous recording feature. 4. Added ability to remotely configure radio devices and audio matrix. 5. Improved layout of status screen. 6. Added remote management capability. Changes in V8.80V ----------------- 1. Corrected problem with audio matrix switching. 2. Fixed minor issue with signal level message from various WJ receivers. 3. Fixed problem with VAD when using some wave formats for digital audio logging. Changes in V8.80R ----------------- 1. Added support for TCP/IP radio connections. 2. Added support for audio matrix switching. 3. Corrected problems with squelch & volume controls on all receivers. 4. Improved throughput of Cubic driver. 5. Corrected issue where some flow control settings were not being reset when the special reset was invoked. 6. Corrected minor issues related to squelch & volume control on remote radios. Changes in V8.80J ----------------- 1. Fixed problem that could occur when a remote server was not enabled to use VAD and the base station was. Changes in V8.80I ----------------- 1. Fixed incorrect range on WJ8711/8712 RF gain knob. 2. Fixed WJ 8712 operation. 3. Improved support for specialized radios. 4. Added support for Rockwell-Collins 95S receiver. 5. Added feature to allow all or selected rows in a column to be changed. 6. Added support for PRO-96 with V Scanner. 7. Reorganized modem and remote site dial-up configuration. 8. Added modem support for various radios. 9. Added support for advanced PRO-96 type II trunk table. 10. Improved handling of various PRO-96 special trunk settings. 11. Improved memory upload to not require radio keypad operations on PRO-96. 12. Added automatic update check to product. 13. Improved PRO-96 upload/download speed. 14. 15. 16. Corrected crash after reading empty PRO-96 V folder. 17. Corrected problem with ID codes on PRO-96. 18. Corrected problem with ID list lookup in engine. 19. Implemented DPL, LTR and MOT low-speed handshake decoding in sound card decoder. 20. Corrected problem with WaveTone decoder where de-emphasis filter was not operating. 21. Added Web Grabber feature. 22. Corrected "missing member" error message in tactical display. 23. Corrected problem that caused crashe when starting to scan. 24. Fixed minor issue with section colors on S-Meter display. 25. Improved ID code display in tractical status. 26. Corrected inverted codes on WaveTone DPL decoder. 27. Problem with step size in PRO-96 UHF Type II trunk settings corrected. 28. Added copy-back and copy-back-resume buttons to the main scanning tool bar. 29. Fixed minor problem on spectrum analyzer display that caused missing points. 30. Fixed minor problem on band scope display that caused missing points. 31. Fixed problem with digital audio logger that cause crash when using 44 kHz format. Changes in V8.79 ----------------- 1. Fixed problem with disconnecting with network-connected radios. 2. Fixed problem with scan list dissapearing. 3. Added 19.2 kBaud to AR-8200 & AR-8600. 4. Corrected problems with connecting to remote radios with an empty scan list. 5. Improved performance of WaveTone subaudible PL decoder. 6, Corrected problems with BC895XLT. 7. Corrected some issues relating to scanning EDACS systems on non-trunking radios. 8. Fixed problem that caused scanning not to stop on channels with non-zero VAD fields but VAD feature not present. 9. Improved PCR-1000 driver for faster, more reliable initial connection. 10. Implemented sound card based PL decoder. Connect discriminator (flat) audio output to sound card line input. On the PCR-1000 and R-8500 these connections use the "packet" output jack. Use "add decoder" in the radio configuration dialog to create an instance of the decoder and associate it with an existing radio. Note that only PL tones are decoded at this time. Other subaudible signalling types such as DPL & LTR will be added in the near future. Please address any performance observations to help@scanstar.com. 11. Corrected problem with AGC modes on Cubic LCR-2000. 12. Made changes to DC440 driver to work better with R8500. 13. Changed squelch default on Cubic LCR-2000 to -113 dBm. 14. Fixed problem with channel initialization that caused default gain of -1 dB and incorrect agc mode settings. 15. Fixed additional problems with R8500 driver. 16. Implemented new RF band scope window. 17. Corrected problem that occured when two radios in use at the same time request the same audio input channel. 18. Corrected problem that caused missing DLL error for NETAPI32.DLL on systems with no NETBIOS present. 19. Corrected problem that caused IE:IVAL error on Cubic receivers. 20. Improved handling of Cubic BITE errors. 21. BITE errors are now reset after fault dialog is displayed. 22. Corrected problem in Cubic LCR-2000 driver that sent an invalid bandwidth under some circumstances. Changes in V8.73 ---------------- 1. Implemented default audio record format feature. 2. Fixed audio record problems with multi-channel devices. 3. Audio sound bites are now limited to 1 hour maximum. 4. Corrected problem with CDR-3150 squelch level knob. 5. Digital audio logger formatted now has system-wide default ability. 6, Fixed scan problem that caused scanning to stop when a non-zero VAD value was seen. 7. Corrected digital audio logger disk space checking. 8. Corrected VAD bug that caused invalid output on some sound bites. 9. Fixed problems with sound system configuration. 10. Improved system shutdown handling. Changes in V8.64 ---------------- 1. Fixed problem with audio gaps when using high delay channels. 2. Fixed problems with NT service installation and control. 3. All remote agent files are now in a common directory on the windows drive. 4. Fixed problems using OptoCom and PCR-1000. 5. Fixed problem with initial startup when no radios were configured. 6. Implemented VAD.